MEDIT Link: Creating Tooth Libraries
Transform scans into anatomy libraries for Magic Clinic CAD. Learn the digital workflow with Smart Dent Academy.
Transform scans into anatomy libraries for Magic Clinic CAD. Learn the digital workflow with Smart Dent Academy.
The Routine Nobody Sees: Transforming Scans into Digital Libraries
📊 Quick Technical Summary
The creation of anatomy libraries from intraoral scans, using the Ort Simulation application, integrates natural teeth or models into workflows such as Magic Clinic CAD. This process, despite focusing on dental segmentation, requires orthodontic simulation for export, ensuring data versatility for restorations or diagnostic wax-ups.
- Main Tool: Ort Simulation
- Objective: Generation of anatomy libraries
- Export Formats: .STL, .PLY, .OBJ
- Minimum Requirements: Two arches, 10 elements per arch
How many times does a tight deadline force us to improvise? That complex case that requires meticulous planning, but the database for digital design is always generic. The frustration of having to adapt standard anatomies when the ideal would be to start from a more real, more personalized base, is a silent pain that many of us know well.
The insecurity of submitting a case to the lab with little information or limited references is real. Rework, the hidden cost of materials and team hours, all directly impact margin and reputation. It's a seemingly endless cycle, where the pursuit of efficiency and predictability clashes with the limitations of the resources we have at hand.
In the busy daily routine, the idea of transforming a patient's scan into a personalized tooth library for use in CAD software is almost a dream. Having the exact anatomy of an adjacent tooth, an antagonist, or even a specific diagnostic wax-up available changes the way we approach planning and execution. It's about taking a leap in quality, in precision, without adding unnecessary complexity.
For those looking to optimize this process, the Ort Simulation application, integrated into a reliable digital workflow, emerges as a surprising tool. Surprising because its initial focus is different, orthodontic simulation, but its ability to generate segmented dental libraries for Magic Clinic CAD completely transforms the scenario. This is not an empty commercial promise, but a practical observation: the software, which is already part of the ecosystem of those who use MEDIT Intraoral Scanners, offers a direct path to the personalization we so desperately need.
Of course, to achieve this export, some steps must be followed within the Ort Simulation environment. Tooth segmentation, for example, is a crucial point. The software does initial work, but manual review and correction of small details ensure that each dental element is captured with the precision necessary to become a perfect donor anatomy.
Experience shows that dedicating time to refine this segmentation, adjust contours, and ensure that only the desired surface is selected, is an investment that pays off. After all, the quality of the generated library will be directly proportional to the care taken at this stage. The result is an STL, OBJ, or PLY file that can be used not only in Clinic CAD for dental restorations, but also in other software for diagnostic wax-ups, such as Medit Design.
📋 Protocol for Creating Anatomy Libraries with MEDIT Link and Ort Simulation
This protocol details the process for transforming an intraoral scan into a library of personalized dental anatomies, using the Ort Simulation application, for use in CAD software such as Magic Clinic CAD or Medit Design.
Required Materials and Equipment:
- MEDIT Intraoral Scanner (such as Medit i600)
- MEDIT Link Software
- MEDIT Ort Simulation Application
- MEDIT Magic Clinic CAD Application (for library use) or Medit Design (for STL/OBJ/PLY export)
- Patient or mannequin scan (two arches, with at least 10 dental elements per arch)
Step-by-Step Procedure:
-
Step 1: Perform the Scan
Scan the patient's or mannequin's maxilla and mandible using an intraoral scanner. It is essential that the scan contains both arches and a minimum of 10 dental elements per arch for Ort Simulation to perform the orthodontic simulation, an essential step for segmentation.
-
Step 2: Open Ort Simulation
After scanning, open the MEDIT Ort Simulation application through MEDIT Link. The software will automatically load the case. Confirm that the maxilla and mandible assignment is correct.
-
Step 3: Mark Midlines
Follow the instructions of the Ort Simulation wizard, marking the midline point on the maxilla and mandible. Although it is possible to trim excess scanning at this stage, the main focus is on marking the lines to proceed.
-
Step 4: Start Simulation for Segmentation
Proceed to the simulation stage. The software will compare the arches and begin the automatic segmentation process of the teeth. This segmentation is the basis for creating the anatomy library.
-
Step 5: Check and Correct Segmentation
Carefully review the automatic segmentation performed by the software's artificial intelligence. Use the editing tools (selection and deletion brushes) to correct any failures, such as missing areas or excess selection in each dental element. Precision at this stage is crucial for the quality of the library.
-
Step 6: Confirm Edits and Proceed
After all corrections to the segmentation, confirm the edits so that the program can proceed with the orthodontic treatment simulation.
-
Step 7: Go Through Orthodontic Simulation Steps
Even if the interest is not in the orthodontic simulation itself, it is necessary to go through all the wizard steps (including advanced dental movement adjustments, if presented) until the export option is reached.
-
Step 8: Export to Magic Clinic CAD
In the final step, click the export button for Magic Clinic CAD. Define a name for the library (e.g., "Smart Dent Anatomy") and ensure that the "Export as library" option is selected. Confirm the export. A success message will be displayed, and the library will be available in Clinic CAD upon next execution.
-
Step 9: Export Segmented Teeth as STL/OBJ/PLY (Optional)
Alternatively, or additionally, it is possible to export the segmented teeth in universal formats such as STL, PLY, or OBJ. Select the option "Export segmented teeth only", choose the format and export type (closed or surfaces only). This option is ideal for use in other design software, such as Medit Design for diagnostic wax-ups.
-
Step 10: Finalize and Exit
Close the Ort Simulation application, choosing to exit without saving the orthodontic simulation if the objective is only to generate the library. The exported libraries will already be saved for use.
⚠️ Points of Attention:
- The condition for orthodontic simulation (and, consequently, the export of anatomies) is to have two complete arches and at least 10 dental elements per arch. Without this, the process will not proceed.
- The precision of manual segmentation is directly proportional to the quality of the generated anatomy library.
- The quality of the initial scan impacts the entire process; clean and complete scans reduce the need for corrections.
It's clarity, investment security, and predictable financial return. The ability to transform a scan into a personalized anatomical reference is a game-changer. It ceases to be a complicated process and becomes a natural part of an intelligent digital workflow.
This means less speculation, more precision. Less rework, more confidence. And, ultimately, a clinical result that reflects the care and personalization each patient deserves. The decision to incorporate these tools is not just technical, but strategic, positioning the professional ahead, with more control over each stage of the restorative or rehabilitative process.
💎 Highlight: MEDIT i600 Intraoral Scanner
The foundation of the entire digital workflow begins with capture. The MEDIT i600 Intraoral Scanner is a central element for this transformation, offering the precision and speed necessary to start the process of creating dental libraries with excellence.
- Unmatched Clinical Precision: Average of 10.9 μm (±0.98 μm) for full arch, ensuring that the anatomical details for library creation are as faithful as possible.
- Fast and Fluid Scanning: Up to 35 FPS with continuous 3D video capture. Less chair time, more patient comfort, and more complete data for planning.
- Full Color Capture: With 8-bit depth, it enhances anatomical reading and facilitates communication with the lab, essential for identifying fine details in segmentation.
- Open Architecture: Export in STL, OBJ, and PLY, ensuring unrestricted compatibility with CAD/CAM software and 3D printers. Freedom of choice without monthly fees or additional license costs.
- Lightweight and Ergonomic: Weighing only 245g, it reduces clinical fatigue, allowing for longer and more comfortable sessions.
- 180° Reversible Tip: Optimizes intraoral access, facilitating capture in hard-to-reach areas.
- Autoclavable Tip: Ensures the highest biosafety standards, essential in the clinical environment.
- Medit Link Software Included: Complete and economical solution that transforms prosthetic rehabilitation, restorative dentistry, and orthodontics.
Investing in a scanner like the Medit i600 is investing in the freedom and efficiency of the digital workflow, ensuring that the basis for your tooth libraries is always of high quality.
Learn more about the MEDIT i600 Intraoral Scanner
Vídeos relacionados
Perguntas Frequentes
What are tooth libraries and how are they created in MEDIT Link?
These are collections of digital dental anatomies generated from intraoral scans. They are created using the Ort Simulation application in MEDIT Link.
What is the main tool used to generate these anatomy libraries?
The main tool for generating anatomy libraries from scans in MEDIT Link is the Ort Simulation application.
What are the minimum requirements for creating a tooth library in MEDIT Link?
To generate the library, scans of two arches and a minimum of 10 dental elements per arch are required.
What are the anatomy libraries created in MEDIT Link used for?
They allow professionals to use more realistic and personalized anatomies in CAD software, such as Magic Clinic CAD, for restorations and diagnostic wax-ups.
In what formats can tooth libraries be exported?
Tooth libraries can be exported in .STL, .PLY, and .OBJ formats.
What are tooth libraries and how are they created in MEDIT Link?
These are collections of digital dental anatomies generated from intraoral scans. They are created using the Ort Simulation application in MEDIT Link.
What is the main tool used to generate these anatomy libraries?
The main tool for generating anatomy libraries from scans in MEDIT Link is the Ort Simulation application.
What are the minimum requirements for creating a tooth library in MEDIT Link?
To generate the library, scans of two arches and a minimum of 10 dental elements per arch are required.
What are the anatomy libraries created in MEDIT Link used for?
They allow professionals to use more realistic and personalized anatomies in CAD software, such as Magic Clinic CAD, for restorations and diagnostic wax-ups.
In what formats can tooth libraries be exported?
Tooth libraries can be exported in .STL, .PLY, and .OBJ formats.
What is the main objective of creating tooth libraries with MEDIT Link?
The main objective is to transform intraoral scans into digital anatomy libraries, which can be used in CAD workflows for restorations or diagnostic wax-ups.
Which MEDIT Link tool is used to generate these anatomy libraries?
The main tool used for generating anatomy libraries from scans is the Ort Simulation application.
What are the available export formats for the generated anatomy libraries?
The available export formats for anatomy libraries are .STL, .PLY, and .OBJ.
What are the minimum scanning requirements to create a tooth library?
The minimum requirements are two scanned arches, containing at least 10 dental elements per arch.
What is the creation of anatomy libraries from intraoral scans?
It is the process of transforming scans of natural teeth or models into digital libraries, using the Ort Simulation application, for use in digital workflows such as Magic Clinic CAD.
What is the main tool used to generate these anatomy libraries?
The main tool is the Ort Simulation application, which allows for dental segmentation and data export.
What export formats are compatible with this process?
The compatible export formats are .STL, .PLY, and .OBJ, offering versatility for various applications.
What are the minimum requirements for creating these libraries?
Two arches are required, with a minimum of 10 elements in each arch, for the creation of anatomy libraries.